How to control the humidity of the computer room effectively?
Mar 01, 2022
How to control the humidity of the computer room effectively?
What should I do if the humidity in the computer room is very high?
Once the humidity in the computer room exceeds the standard, it is easy to form a water film on the surface of the components or dielectric materials, resulting in "conductive paths" and arcing, thereby reducing the reliability of the circuit. Some plastic and rubber products due to water absorption, cause deformation or even damage.

Under normal conditions, it is most appropriate to control the humidity of various electrical equipment in the equipment room at about 40%-60%. When the ambient humidity of the equipment room exceeds 65%RH or above, the humid air will cause different degrees of damage to the electrical equipment in the equipment room, affecting the normal operation and safety of the equipment room!
The equipment in the computer room is responsible for the important tasks of data exchange, storage, and transmission. A large number of precision instruments and equipment, such as servers, exchangers, routers, disk arrays, etc., have high requirements on the indoor environment. For normal operation and safety, environmental humidity must be controlled scientifically and reasonably.
So, what should I do if the ambient humidity in the computer room is too high? How to effectively control the humidity of the computer room?

In terms of humidity control in the computer room, the dehumidifier can provide the most suitable humidity environment for the safe operation of the equipment in the computer room, and completely solve the humidity problem in the computer room. Only by installing a dehumidifier in the computer room can automatic control of unmanaged humidity be achieved. It is currently the most effective humidity control equipment and moisture-proof measure widely used in the computer room environment.
Regarding the ambient humidity of the computer room, there is another national standard GB 2887-89 on-site technical conditions for computer stations. 4.4.1.3 stipulates that the ambient humidity standard of the computer room is: Class A 45%-65%RH, Class B 40%-70%, Class C 30 %-80%RH. The standard of the general communication room should meet the Class A standard. Communication industry standard communication room electrostatic protection general rules VD/T 754-95 also has environmental temperature and environmental humidity standards: 4.2 The relative humidity in the environment is required to be between 40%~65%RH.
The higher the humidity in the equipment room, the greater the impact and damage to the equipment. The dehumidifier function of the computer room provides the most suitable humidity environment (relative humidity between 45%-55%) for the safe operation of the equipment in the computer room.
In short, the selection of dehumidifiers in the computer room needs to be comprehensively considered according to the actual requirements and space area of the computer room. Different types of computer rooms, different areas, and different requirements may have different choices. Choosing a suitable lifting dehumidifier for reasonable humidity control can better meet the moisture-proof requirements and equipment requirements of the environmental humidity of the equipment room. According to the customer's specific area height, it is attractive to provide customers with appropriate dehumidification products to keep the machine room dry and avoid possible problems.